China OEM Hydraulic Hose Fittings Factory – 90 Degree PTFE Hose End Fitting Black for PTFE Hose Only – Yibai Manufacturer and Supplier | Yibai

OEM Hydraulic Hose Fittings Factory – 90 Degree PTFE Hose End Fitting Black for PTFE Hose Only – Yibai

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our well-equipped facilities and excellent excellent management throughout all stages of creation enables us to guarantee total buyer satisfaction for Fuel Line Clamp, Water Hose Adapter, Hose Connector, We also ensure that your choice is going to be crafted with the highest good quality and dependability. Be sure to feel free of charge to contact us for additional information.
OEM Hydraulic Hose Fittings Factory – 90 Degree PTFE Hose End Fitting Black for PTFE Hose Only – Yibai Detail:

* Features

How To Install PTFE Hose Fittings – Step by Step Installation Guide
This is a step by step guide that shows you precisely what to do. Follow these steps to have your PTFE hose fittings installed just like a Pro. Step 1 – Cutting PTFE Hose
First we need to mark the cut position on the PTFE hose. To do this we wrap a piece of masking tape around the hose to cover the cut we are going to make. This serves two purposes, #1 to allow a pencil mark to be made in the exact position and #2 it will stop the stainless steel braid from flaring out as we cut.
Most people assembling hoses at home will use a fine tooth metal saw to cut the hose, it’s the sort of tool you’ll already have. You could use hose shears or other commercial hose cutting equipment if you have access to it.
Secure the hose before cutting in the plastic vice jaws. Cut square and let the saw blade do the cutting – do not force it. To install the PTFE hose fittings you will need to clean away any burrs from the PTFE tube. Any frayed stainless steel braids may be trimmed with snips. Step 2
We are now going to fit the PTFE hose fitting socket nut on to the PTFE hose. But first we should check the hose is round by gently squeezing with pliers. We also insert the PTFE hose fitting at this time as a check that the i.d. is round – remove it and put it to one side. Before removing the masking tape, slide the socket nut onto the PTFE hose. Be sure it’s the correct way around. Step 3 – Flaring The Braid
Using a small screwdriver or pick, gentle expand the stainless steel braid away from the PTFE tube. Work all around the tube until done. Care should be taken to ensure the PTFE hose is not damaged. Step 4 – Installing the Olive / Ferrule
Push the olive / ferrule onto the end of the PTFE tube and under the stainless steel braid. Ensure no braid lies between the tube and the olive / ferrule. This is important because it is not possible to install PTFE hose fittings and have a leak free seal if a piece of braid is caught beneath the olive. Complete the installation by pressing the end of the olive / ferrule against a flat surface. Inspect to ensure the PTFE tube butts up squarely and fully against the inside shoulder of the olive / ferrule. Step 5
Lubricate the threads on the socket nut, the hose end and also lubricate the PTFE hose fitting nipple using light oil. Insert the PTFE hose fitting into the PTFE hose by holding the hose and pushing the hose end nipple into the tube with a combined twisting pushing action. Check it is in as far as it will go. Step 6
Hold the socket nut in the vice jaws and, keeping the assembly square, start to engage the socket and PTFE hose fitting thread. It will be possible to start the threads by hand and to be sure the threads are correctly aligned. Step 7
Using the correct size spanner, tighten the PTFE hose fitting into the socket nut. Apply oil to the thread as you tighten up the union. Continue to tighten the PTFE hose fitting into the socket until you have a gap of approximately 1mm. Align the flats for a professional finish.

OEM Factory PTFE 90 degree fitting
OEM ODM Factory PTFE 90 degree fitting
OEM ODM Chinese Wholesale PTFE 90 degree fitting

* Detail


Product detail pictures:

OEM Hydraulic Hose Fittings Factory –  90 Degree PTFE Hose End Fitting Black for PTFE Hose Only – Yibai detail pictures

OEM Hydraulic Hose Fittings Factory –  90 Degree PTFE Hose End Fitting Black for PTFE Hose Only – Yibai detail pictures

OEM Hydraulic Hose Fittings Factory –  90 Degree PTFE Hose End Fitting Black for PTFE Hose Only – Yibai detail pictures

OEM Hydraulic Hose Fittings Factory –  90 Degree PTFE Hose End Fitting Black for PTFE Hose Only – Yibai detail pictures

OEM Hydraulic Hose Fittings Factory –  90 Degree PTFE Hose End Fitting Black for PTFE Hose Only – Yibai detail pictures


Related Product Guide:

Our solutions are broadly acknowledged and dependable by users and may meet consistently developing economic and social requires for OEM Hydraulic Hose Fittings Factory – 90 Degree PTFE Hose End Fitting Black for PTFE Hose Only – Yibai , The product will supply to all over the world, such as: Lyon, Vietnam, Albania, Now, we professionally supplies customers with our main products And our business is not only the "buy" and "sell", but also focus on more. We target to be your loyal supplier and long-term cooperator in China. Now, We hope to be the friends with you.
  • This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By James Brown from Nairobi - 2018.11.11 19:52
    Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By Teresa from New Delhi - 2018.08.12 12:27

    Leave Your Message